Standard project 2Mg-04-3

https://proekt.sx

Online store for reuse projects

Cart is empty

Did not you find what you were looking for? Ask us! We have archives of 140 TB. We have all modern reuse projects and renovation projects for Soviet standard buildings. Write to us: info@proekt.sx


Standard project 2Mg-04-3

Base price with VAT
Discount price
Price $1,500.00
Discount
Price $1,500.00
Index: 19012101
Data Sheet: Working documentation including estimates
Sections: all sections
Data volume: 623 MB
File Format: *.pdf, *.xlsx
Expert opinion: a positive
Working documentation including estimates for a comprehensive overhaul of the kindergarten building, standard project 2Mg-04-3.
Technical and economic indicators:
Fire resistance degree: II
Floors: 3+basement
Total area of ​​the building (according to BTI): 2867,0 m2
Building area (according to BTI): 909,9 m2

General information.

 The building of the kindergarten, made according to the standard project 2Mg-04-3, 3-storey, has a complex shape in plan. External walls - expanded clay concrete blocks. The roof is flat, low-slope, covered with rolled material, the drain is internal, organized. Two-flight stairs from prefabricated reinforced concrete flights of stairs and landings. On the ground floor: - security room, 4 group cells, consisting of a group room, a bedroom, a pantry and a locker room, a medical unit, a gym, a laundry room for storage linen, a security room and an electrical panel room. On the second floor: - 10 group cells, consisting of a group room, a bedroom, a pantry, a dressing room and a bathroom. On the third floor: - administrative premises, a music hall and a catering unit. In the technical underground: - technical rooms Communication between the floors is carried out with the help of 2 evacuation stairs, located dispersed in the volume of the building. One of the stairs has access to the basement, separated by a fire cut. Exit to the roof is carried out using a typical fire escape. For a conditional mark of 0.000, the level of the finished floor of the first floor is taken. External walls are brick load-bearing, 510 mm thick. The project provides for the insulation of external walls according to the "Thermomax" system; thicknesses 100 mm. Internal longitudinal walls brick load-bearing thicknesses. 510 mm. The rigidity of the building is ensured by the presence of transverse brick walls. Spatial rigidity is ensured by the joint work of load-bearing walls and ceilings. The ceiling above the basement is prefabricated from ribbed and hollow-core slabs, the interfloor ceiling is made from round-hollow slabs. The roof is non-attic, insulated with a low-slope roof covered with rolled material. As part of the overhaul, an external organized drain is provided.

Authorization