public toilet project

https://proekt.sx

Online store for reuse projects

Cart is empty

Did not you find what you were looking for? Ask us! We have archives of 140 TB. We have all modern reuse projects and renovation projects for Soviet standard buildings. Write to us: info@proekt.sx


toilet project

Base price with VAT
Discount price
Price $278.00
Discount
Price $278.00
Index: 64.120.298
Data Sheet: Project documentation including estimates
Sections: all sections
Data volume: 64 MB
File Format: editable formats
Public toilet project. Project documentation including estimates for the construction of a public toilet.
Building area, m2: 74,0
Total area, m2: 41,5
Construction volume, m3: 229,8
Above el. 0.000, m3: 229,8

General data on the project

The toilet building is one-story. The building of the public toilet houses the public toilet and ancillary facilities. A separate entrance is provided to the technical room. The roof is cold, the coating is rolled galvanized sheet with a polymer coating. Access to the attic is provided through an insulated hatch with a fire resistance rating of EI60. For a relative mark of 0,000, the mark of the clean floor of the first floor was taken. The toilet building is rectangular, with plan dimensions of 13,47 x 3,87 m with a ledge of 5,87 x 0,8 m, one-story. The designed building belongs to the category of public buildings, functional fire hazard class F3.5, fire resistance of the building - III, constructive fire hazard class - C1. The height from floor to ceiling of the 1st floor is 3,25m. External walls - made of aerated concrete Aeroc Classic 375 mm thick, made with blocks of aerated concrete D500, B 2,5 F 50, on glue. Reinforcement of aerated concrete masonry of walls made of cellular concrete with a thickness of 375 mm should be performed with reinforcement 2f10A500S in every 4 rows. Under window openings, make additional reinforcement with reinforcement 2f10A500S. Reinforcement indent from the edge of the block - 60mm. Partitions with a thickness of 100 mm should be made of moisture-resistant GKL Giprok, along metal thin-walled racks 75mm. Plaster the walls with Weber-Vetonit mortar, thickness 10mm. Plaster ceilings with Weber-Vetonit mortar. Roof with an external organized drain, roof material - galvanized rolled sheet with a polymer coating. Dormer windows with a crate and installation of a metal mesh with a cell of 10 mm are provided for ventilation. Install metal umbrellas made of galvanized sheet with a polymer coating above the veterinary channels on the roof. Treat all load-bearing and enclosing structures made of lumber with antiseptics and flame retardants. The metal elements of the fences must be painted with group IIa paintwork, with a total thickness of 80 microns. in three top coats, in accordance with SNiP 2.03.11-85 "Protection of building structures against corrosion". Attic ceiling made of monolithic reinforced concrete, thickness 140mm, with insulation with basalt wool, thickness 120mm, density 80-90kg/m3. Lintels made of monolithic reinforced concrete, insulated with basalt wool with a density of 130kg/m3, insulation thickness 50mm. Metal-plastic window blocks of individual manufacture with single-chamber double-glazed windows, mounted according to the manufacturer's technology. Complete with window blocks, install flashings made of galvanized sheet with a polymer coating and window sills. External doors - metal insulated, internal - wooden, deaf. Fencing of toilet cubicles is to be carried out according to a separate project. Porches, ramps, and floors should be covered with anti-slip ceramic tiles. Insulate the plinth with 80mm thick extruded polystyrene foam boards. Finish the facades with thin-layer plaster. Ramps and porches that are not protected by canopies should be equipped with electric heating. Construction of foundations, marks of the bottom of the pit, solutions for waterproofing foundations and backfilling of sinuses, see the QOL section.

Authorization